Back to Top

Hi, Guest!

  LOKASI :  Kota Tangerang Selatan

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • HACH Instrument
  • HACH DR 6000 UV VIS Spectrophotometer with RFID Technology

HACH DR 6000 UV VIS Spectrophotometer with RFID Technology

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Lusin
Dilihat Sebanyak
:
8 kali
Harga
Rp. 100.000.000
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail HACH DR 6000 UV VIS Spectrophotometer With RFID Technology

HACH DR 6000 UV VIS Spectrophotometer with RFID Technology NEW The DR6000™ is the industry’ s most advanced lab spectrophotometer. It offers high-speed wavelength scanning across the UV and Visible Spectrum, and comes with over 250 pre-programmed methods including the most common testing methods used today. With optional accessories allowing for high-volume testing via a carousel sample changer, and increased accuracy with a sample delivery system that eliminates optical difference errors, this instrument ensures you are ready to handle your wide-ranging water testing needs. Combining the DR6000 with Hach’ s patented TNTplus™ reagent vials, you gain additional accuracy with guided step-by-step testing procedures, while making scratched, flawed or dirty glassware a non-issue due to averaging 10 readings and discarding outliers. The instrument also utilizes RFID technology, allowing it to let you know automatically if your TNTplus reagents have expired, while detecting coefficient factors to avoid errors which can occur in lot-to-lot variations in the chemistries. Partnering all of these features with an integrated QA software package allows for scheduling, documenting and interpreting your needed quality measurements. Your water testing needs, all in one spectrophotometer. * RFID currently available only in US, Anguilla, American Samoa, Australia, Bolivia, Canada, Cayman Islands, Columbia, Dominican Republic, El Salvador, Federated States of Micronesia, Guam, Guatemala, Marshall Islands, New Zealand, Northern Mariana Islands, Palau, Panama, Puerto Rico, and US Virgin Islands. Customers in other countries should order LPV441.99.00002. • Your Water Testing Needs, All in One Spectrophotometer • Accessories for High Volume and High Accuracy Testing Needs • Advanced Quality Assurance at Your Fingertips • Guided Procedures and Elimination of False Readings • Automatically Avoids Errors Your Water Testing Needs, All in One Spectrophotometer The DR 6000 has the most pre-programmed testing methods, including high-speed wavelength scanning across the UV and Visible Spectrum. Accessories for High Volume and High Accuracy Testing Needs A carousel sample changer allows up to seven sequential measurements. The Sipper Module, an instrument-controlled sample delivery system, increases precision by constant optical characteristics. Advanced Quality Assurance at Your Fingertips The DR 6000 comes with integrated QA software for scheduling, documenting and interpreting all of your needed quality measurements. Guided Procedures and Elimination of False Readings The DR 6000, when used with TNTplus® reagent vials, provides the accurate results you need by guiding you step-by-step through your testing procedures. With TNTplus, the instrument averages 10 readings and eliminates outliers, making scratched, flawed or dirty glassware a non-issue. Automatically Avoids Errors RFID* technology automatically updates the program calibration factors when you place a TNTplus reagent box near the DR 6000. The instrument identifies chemistry expiration dates via a barcode on the vials, and detects chemistry coefficient factors to avoid errors that can occur in lot-to-lot variations in the chemistry. * RFID technology currently available only in US, Anguilla, American Samoa, Australia, Bolivia, Canada, Cayman Islands, Columbia, Dominican Republic, El Salvador, Federated States of Micronesia, Guam, Guatemala, Marshall Islands, New Zealand, Northern Mariana Islands, Palau, Panama, Puerto Rico, and US Virgin Islands. What' s in the box • Includes: printed instrument manual, procedure manual on CD, power cords ( 115V and 230V) , universal holder, dust cover, 1-in. square matched glass sample cells, and a universal-adapter Specifications • Data Logger: 5000 data points ( result, date, time, sample-ID, user-ID) • Depth: 18.11 pulg • Dimensions ( H x W x D) : 8.5 in x 19.7 in x 18.1 in ( 215 mm x 500 mm x 460 mm) • Display: TFT 7 inch WVGA color touch • Enclosure Rating: IP20 with closed lid • Includes: 1 x Power Cord ( US, EU) 1x Universal-Adapter 1x Dust Cover Matched pair of 1 inch glass sample cells CD ROM with comprhensive user manual ( en, fr, es, pt, cn) , working procedures, refrence guides for accessories Printed multilingual basic user manaul ( en, es, fr, ja, ko, pt, zh) • Length: 18.1 in ( 460 mm ) • Manual Languages: en, es, fr, ja, ko, pt, zh • Operating Conditions: 10 at 40 ° C, max. 80% relative humidity ( non-condensing) • Operating Mode: Transmittance ( % ) , absorbance and concentration ( wavelength, time) • Optical System: reference beam, spectral • Photometric Accuracy: 5 mAbs at 0.0-0.5 Abs 5 • Photometric Accuracy 2: 2 Abs with neutral glass at 546 nm • Photometric Measuring Range: ± 3 Abs • Power Requirements: 100 to 240 V; 50/ 60 Hz • Sample Cell Compatibility: Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch Optional 100 mm rectangular cell with additional adapter • Scanning Speed: 900 nm/ min ( in 1 nm steps) Source Lamp: Tungsten ( visible range) , deuterium ( UV range) • Spectral bandwidth: 2 nm • Storage Conditions: -25 at 60 ° C max. 80% relative humidity ( non-condensing) • Stray Light: KI-solution at 220 nm < 3.3 Abs/ < 0.05% • User Interface Languages: bg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr • User Programs: 200Warranty: 1 year • Wavelength Accuracy: ± 1 nm • Wavelength Range: 190 to 1100 nm • Wavelength Reproducibility: < 0.1 nm • Wavelength Resolution: 0.1 nm • Wavelength Selection: Automatic, based on method selection • Weight: 24.25 lbs. ( 11 kg)
Tampilkan Lebih Banyak